Feeling brave after my fix on the wacker is there anything I can do with my old genny. It runs fine, starts easy enough but when I plug tools in they are not running well. The motor sounds fine its not struggling but its like its not putting out enough power to the tool. AI is giving me a few things to check or fix. Is it easy enough to do these?

We had these power packs on hire the other month in the hospital they were mint but cost a fortune to buy
 

Attachments

  • Screenshot 2026-10-11 at 12.28.09 pm.png
    Screenshot 2026-10-11 at 12.28.09 pm.png
    256.2 KB · Views: 20
  • Screenshot 2026-10-11 at 12.28.16 pm.png
    Screenshot 2026-10-11 at 12.28.16 pm.png
    375.4 KB · Views: 20
V8Druid

V8Druid

do it as well as you can,but learn to do it better
Feeling brave after my fix on the wacker is there anything I can do with my old genny. It runs fine, starts easy enough but when I plug tools in they are not running well. The motor sounds fine its not struggling but its like its not putting out enough power to the tool. AI is giving me a few things to check or fix. Is it easy enough to do these?

We had these power packs on hire the other month in the hospital they were mint but cost a fortune to buy
all pretty straight forward stuff Jim .... have a look at the commutator first -- if the copper surface isn't 'shiny', coudl well be an oxidisation issue - also check the brushes for free movement and length ..... AVR is, as said, a POP to swap out
 
J

Jimoz

Well-known member
Well after a more in-depth chat with AI and photos of the plate on the Genny it ended up telling me different. I've now ordered a new capacitor. While out there i've checked the oil and its black and about 1/3 up the dipstick so found the drain plug for this so will drain off and change. Probably wait till new capacitor is here and its powering tools ok with that.

It was running okay but we had a breaker plugged into it Friday and it was noticeably underpowered
 

Attachments

  • Screenshot 2026-10-11 at 12.47.37 pm.png
    Screenshot 2026-10-11 at 12.47.37 pm.png
    301.3 KB · Views: 20
  • 20261011_124331.jpg
    20261011_124331.jpg
    201.1 KB · Views: 16
  • 20261011_124338.jpg
    20261011_124338.jpg
    170.7 KB · Views: 15
  • 20261011_132457.jpg
    20261011_132457.jpg
    138.5 KB · Views: 16
S

Stroppymonkey

Well-known member
Well after a more in-depth chat with AI and photos of the plate on the Genny it ended up telling me different. I've now ordered a new capacitor. While out there i've checked the oil and its black and about 1/3 up the dipstick so found the drain plug for this so will drain off and change. Probably wait till new capacitor is here and its powering tools ok with that.

It was running okay but we had a breaker plugged into it Friday and it was noticeably underpowered
I know nowt about generators, but do know capacitors fairly easy to test with correct multimeter (we test them on oil boilers all the time)

I also find AI too bloody helpful. I like to ask (argue) it questions about why the fault I think is the issue shouldn’t be the cause. It will agree with you far too easily .
 
V8Druid

V8Druid

do it as well as you can,but learn to do it better
Well after a more in-depth chat with AI and photos of the plate on the Genny it ended up telling me different. I've now ordered a new capacitor. While out there i've checked the oil and its black and about 1/3 up the dipstick so found the drain plug for this so will drain off and change. Probably wait till new capacitor is here and its powering tools ok with that.

It was running okay but we had a breaker plugged into it Friday and it was noticeably underpowered
's 'cos it's only 2 Kva .... breaker'll draw more than 2000w .... would struggle with a 2kw 9" grinder
alright for drills, saws, lights, etc.
I've a 2.4Kva, Hodna which'll just about run a 9" ... runs the boiler fine when the leccy is off though :giggle::giggle:
 
J

Jimoz

Well-known member
I know nowt about generators, but do know capacitors fairly easy to test with correct multimeter (we test them on oil boilers all the time)

I also find AI too bloody helpful. I like to ask (argue) it questions about why the fault I think is the issue shouldn’t be the cause. It will agree with you far too easily .
Yeh sometimes I have to tell it not to be afraid to offend me.

Its not a problem in this case though because I had no idea what to suggest.
 
J

Jimoz

Well-known member
's 'cos it's only 2 Kva .... breaker'll draw more than 2000w .... would struggle with a 2kw 9" grinder
alright for drills, saws, lights, etc.
I've a 2.4Kva, Hodna which'll just about run a 9" ... runs the boiler fine when the leccy is off though :giggle::giggle:
So do these capacitors wear out or are they either working or not working? As in if the tools are getting power from the genny its working.
 
V8Druid

V8Druid

do it as well as you can,but learn to do it better
So do these capacitors wear out or are they either working or not working? As in if the tools are getting power from the genny its working.
a AI said, they do degrade (or explode even :oops:) but if it's nadgered it won't excite the genny and you'll get no output ... the fact it wouldn't run an overload/ran it badly would indicate power is being generated .... could try poking a bare lead with a finger :p:oops::ROFLMAO: - or running something of a more suitable size for the 2 Kva capacity;)
 
J

Jimoz

Well-known member
Yeh i mean it wasn't a massive breaker just a small one but does work better plugged in to the wall. I will take the chance for how easy they are to swap. Unfortunately dont have a multi meter. I do have a moisture content meter though 🤣
 
S

Stroppymonkey

Well-known member
a AI said, they do degrade (or explode even :oops:) but if it's nadgered it won't excite the genny and you'll get no output ... the fact it wouldn't run an overload/ran it badly would indicate power is being generated .... could try poking a bare lead with a finger :p:oops::ROFLMAO: - or running something of a more suitable size for the 2 Kva capacity;)
Do like in the videos - stick the ends into a bucket of water to see how long it takes to boil 🫣
 
Gecko

Gecko

Well-known member
So do these capacitors wear out or are they either working or not working?
This type of cap is quite similar to a lead acid battery in the way it works. As they age, the electrolyte dries out and/or deteriorates, so yes, the capacitance drops off and the gens output drops - same as the run cap on a motor.

I bought a cheap 2kVA with a briggs engine. Seemed to work fine, but tools had no power. A quick test of the output shows only 160V. A new cap and it was back at full capacity.
Once I had it working, I realised it was too small and replaced it with a 6kVA diesel :ROFLMAO:
 