J
JamieBGW
New member
Morning all, does anybody else here seem to have recurring fuel filter and/or ad blue faults (crystalizing) with their Hitachis? We seem to be replacing fuel filters at a sporadic rate, I know the machine filters are 4 micron and the filter in the refuelling hose is also 4, I would guess the main issue would be the 'rose' which you dip in to the fuel tank to draw the fuel in to the machine would be the issue as it's 30 microns. Has anyone else had these issues and more importantly is there anything that we can do to try and eradicate these issues.. we have diesel bug solution in each of our tanks every 2-3 fills and regular service intervals @ 500hr from Hitachi themselves who change the fuel filters on the refuelling hoses also but on some occasions we only hit 100hrs before the filters get clogged up again. We've had dip & water tests on our tanks which have come back as satisfactory.
The adblue sensor seems to have no tolerance to the slightest bit of moisture neither which is annoying, I can't really see any way around this other than ensuring touch points (e.g. funnel) are clean and dry before use.
The adblue sensor seems to have no tolerance to the slightest bit of moisture neither which is annoying, I can't really see any way around this other than ensuring touch points (e.g. funnel) are clean and dry before use.