Kubota with Tiltrotator

Giles

Giles

Well-known member

Attachments

  • 181F5D06-C8BD-483C-8B66-11ABA3DE6D46.png
    181F5D06-C8BD-483C-8B66-11ABA3DE6D46.png
    665.3 KB · Views: 256
  • 8AAEBA8C-F694-4DD3-AFD6-B69868F81E5A.png
    8AAEBA8C-F694-4DD3-AFD6-B69868F81E5A.png
    887.7 KB · Views: 207
  • AB35F065-FC58-4684-B0EE-4EA5F114520B.png
    AB35F065-FC58-4684-B0EE-4EA5F114520B.png
    823.5 KB · Views: 279
GazCro

GazCro

Well-known member
Yeah they look good 👍 shame about the time it's spent in the bushes 😬who would do that to a new machine 🤦
Saw another canceled order for 47k but not sure if it was Hi spec - might even go that way but it's going to add up to 62k when it's got a tilty on 🤨
There's a difference between a few light marks from working in a tight spot among a few bushes and looking like being buried in the bushes.
 
Furniss

Furniss

Well-known member
20221130_153307.jpg

20221130_153321.jpg
20221130_153325.jpg
20221130_153259.jpg

Called in at wn dealers today when I was passing ..... they have no availability of the ET6.5t till end of next year 🤷....was quite impressed with this 5t they had - great spec and looked nicely put together...bit small for me unfortunately.
 
M

Monkeybusiness

Well-known member
V8Druid

V8Druid

do it as well as you can,but learn to do it better
What are the hoses/services coming off the bucket ram? Can it be easily bypassed to use that circuit for a grab etc?
be the same as my 'Drema's .... 3x1 diverter valve, each circuit ...
closes the ram off and fixes it in whatever position you choose/leave it in and the service goes directly to the QC to power whatever .... mine is for the open/close circuit with a grab on - tip ram/link stays put - if you don't close the 3x1,s the ram shares flow with the QC's att, when connected, so ends up pretty random -- QC,s're pressurised constantly ... as I found, when I had a hose between the 3x1 and the QC go one day -- spectacularly :oops::( ... missed Simon by millimetres, but covered the side of me boxes
 
Furniss

Furniss

Well-known member
be the same as my 'Drema's .... 3x1 diverter valve, each circuit ...
closes the ram off and fixes it in whatever position you choose/leave it in and the service goes directly to the QC to power whatever .... mine is for the open/close circuit with a grab on - tip ram/link stays put - if you don't close the 3x1,s the ram shares flow with the QC's att, when connected, so ends up pretty random -- QC,s're pressurised constantly ... as I found, when I had a hose between the 3x1 and the QC go one day -- spectacularly :oops::( ... missed Simon by millimetres, but covered the side of me boxes
What he said 🙂
 
Furniss

Furniss

Well-known member
Went to look at a job the other day and part of it involves a decent dig out ....nothing major but a decent bit - by the time the job comes round i expect to be on a 6t and tilty, the machine may have top hitch but if it's direct mount only would a 6t machine handle a 3ft bucket under a tilty for digging out if it's not too hard ?......couldn't imagine a 2ft digging bucket being the biggest in my arsenal for that kind of work.
 
Top